REFORGE
Atari 2600 / F101
CONFIRMED

TIA render: P0>P1 fixed priority + 250-line window restores the score/lives bands

STATUS
CONFIRMED
AREA
Timing / bus
RECORDED
2026-06-11
PUBLIC SOURCE
Research dossier / finding 101
RECORD ID
atari2600-f101
SNAPSHOT
a58ea4ac37c644e9

(a) render_scanline_from_snap drew P1 after P0 (P1 won overlaps); real TIA fixed priority is P0>M0>P1>M1>BL>PF. Draw order swapped.